Auckland Wellington FRIDGE CFC DISPOSAL
ozon-layer killing CFC refridgerant??
==== GOOD ======
you have two options for proper degassing:
1) drop off the fridge AT NIGHT at the gate of
Fisher and Paykel Recycling Plant in East Tamaki -- 14 Allens Rd.
2) or you bring it to
Constellation Drive Refuse Transfer Station - 4 Home Pl, Mairangi Bay
478 9888 AND PAY $15 for up to two items.
===== BAD ======
if you bring it to the Devonport Transfer Station -- 27 Lake Rd, Devonport -- 445 6914
it will be brought to "a scrap metal place in south auckland" where they crush the fridges and release CFCs into the atmosphere... which is against the Montreal Convention to protect the ozone layer. This costs you only $10.
======== INFO =================
auckland regional council cfc mairangi
CFCs of OLD FRIDGE DISPOSAL CFC degassing fridge freezer
Fridge Retirement Scheme From Strength To Strength
Thursday, 23 October 2008, 3:58 pm
Press Release: Fisher And Paykel
Media release
Auckland Fridge Retirement Scheme Goes From Strength To Strength
A unique fridge retirement programme has been so successful it has been extended, offering Aucklanders another chance to recycle their old fridges for free and support Ronald McDonald House Auckland.
400 refrigerators have been taken away and recycled as part of the Energy Efficiency and Conservation Authority.s (EECA) ENERGYWISE. initiative to make homes more energy efficient. The project is run in conjunction with Fisher & Paykel Appliances.
The target has been achieved two months ahead of schedule, and demand has been so great the trial programme has been extended.
Under the scheme Aucklanders are getting a helping hand to rid their homes of inefficient fridges with old refrigeration appliances taken away and recycled for free. Householders have the choice of a $25 payment or donating the amount to Ronald McDonald House Auckland. To date over 55% of consumers have chosen to make the donation to the charity, which is a .home away from home. for families from all over New Zealand whose desperately ill children require potentially lifesaving specialist treatment in Auckland.
Fisher & Paykel Appliances has been removing old fridges in working condition from houses in the greater Auckland region, then de-gassing and recycling them at the company.s dedicated recycling plant for a number of years.
Fisher & Paykel Appliances. Recycling Manager George Gray says .We have always been committed to taking away and recycling old appliances for customers who have purchased a new Fisher & Paykel product from one of our retailers. Under this scheme we are also removing old fridges and freezers from anywhere across greater Auckland for free.
.We are thrilled with the results to date, particularly the number of appliances and donations to Ronald McDonald House Auckland. We would like to thank everyone involved for making this programme such a success and encourage people to recycle their inefficient appliances..
Mr Gray adds: .Taking these appliances out of use can save householders on power costs while benefiting the environment at the same time. Around a third of all fridges and freezers were made before the phasing out of CFCs, making them harmful on the environment..
To be eligible for retirement, fridges and freezers must be at least five years old, in working condition and at least 100 litres in size.
The fridge retirement pilot is part of the New Zealand Energy Efficiency and Conservation Strategy.s goal for better performing products. Older model fridges typically use two to three times more electricity than new ones . and with about 450,000 old, inefficient fridges and freezers in use throughout New Zealand, the potential for savings is huge.
To request a fridge pick up from Fisher & Paykel Appliances, Auckland residents can call the fridge pick up line on 273 6852 or email HomeDeliveries@fp.co.nz
ENDS
About Fisher & Paykel Appliances. Recycling Plant: Fisher & Paykel Appliances. principles are founded in recycling and a commitment to safe environmental processes. Back in 1993, the company started independently taking back old appliances, marking the start of its appliance take-back scheme. Today the company has six staff working full time in its dedicated East Tamaki recycling centre which deals with about 40,000 old washers, dryers, cookers, refrigerators and freezers every year. An estimated 1,600 tonnes of separated materials and 800 tonnes of composite materials are recovered and sold to various merchants for reprocessing and recycling every year.
Aucklanders get helping hand to pull the plug on old, inefficient fridges
21 July 2008
Aucklanders are getting a helping hand to rid their homes of inefficient fridges under a new scheme which sees old refrigeration appliances taken away and recycled for free . and the householder rewarded with $25.
The project is part of the Energy Efficiency and Conservation Authority.s (EECA) ENERGYWISE. initiative to make homes more energy efficient and is run in conjunction with Fisher & Paykel.
Fisher & Paykel will remove old fridges in working condition from houses in the greater Auckland region, then de-gas and recycle them at the company.s dedicated recycling plant. Householders have the choice of a $25 payment or alternatively donating the amount to Ronald McDonald House Auckland.
To be eligible, fridges and freezers must be at least five years old, in working condition and at least 100 litres in size.
Fisher & Paykel.s Recycling Manager George Gray says the company has operated a full recycling plant at East Tamaki for more than 15 years where it breaks down and recycles appliances from all over the North Island, Christchurch and Dunedin.
.We have always been committed to taking away and recycling old appliances for customers who have purchased a new Fisher & Paykel product from one of our retailers. Now under this scheme we will remove old fridges and freezers from anywhere across greater Auckland for free,. says Mr Gray.
He adds that outdated refrigeration appliances are much less efficient than new ones and can use up to three times more electricity.
.Taking these appliances out of use can save householders on power costs while benefiting the environment at the same time. Around a third of all fridges and freezers were made before the phasing out of CFCs, making them harmful on the environment,. he says.
EECA Chief Executive Mike Underhill says many Kiwi homes have two fridges running at a significant cost.
.It.s likely that one of these is the old, inefficient fridge that has been shifted to the garage instead of recycled. This energy guzzler is costing around $200 or $300 a year to run and the chances are it is sitting nearly empty half the time. By getting rid of this fridge, both the owner and New Zealand comes out better off,. says Mr Underhill.
.We estimate there are about 450,000 old and inefficient fridges and freezers in use throughout New Zealand, so the potential to save energy and money is huge..
The fridge retirement project is part of the New Zealand Energy Efficiency and Conservation Strategy.s goal for better performing products.
To request a fridge pick up from Fisher & Paykel, Auckland residents can call the fridge pick up line on 273 6852 or email HomeDeliveries@fp.co.nz
ENDS
About Fisher & Paykel.s Recycling Plant:
Fisher & Paykel.s principles are founded in recycling and a commitment to safe environmental processes. Back in 1993, the company started independently taking back old appliances, marking the start of its appliance take-back scheme. Today the company has six staff working full time in its dedicated East Tamaki recycling centre which deals with about 40,000 old washers, dryers, cookers, refrigerators and freezers every year. An estimated 1,600 tonnes of separated materials and 800 tonnes of composite materials are recovered and sold to various merchants for reprocessing and recycling every year.
For further information please contact:
Tamara Lee
Communications Advisor, EECA
09 374 3810 / 027 406 1863
tamara.lee@eeca.govt.nz or
Joanna Redfern-Hardisty
Fisher & Paykel
021 632 003
jo@nzsponsorship.co.nz
Be aware that they check for two sources of gas. The coolant gas (which you could do something about) and the gas which was used to puff up the foam insulation in the doors and so on (which you can't).
When PUR-foam is degassed according to the known method, for instance only about 75% of the CFC gases present therein can be extracted.
CFC-12
(R-12), usually sold under the brand name Freon-12, is a chlorofluorocarbon halomethane (CFC), used as a refrigerant and aerosol spray propellant. Its manufacture was banned in the United States and many countries in 1994 due to concerns about damage to the ozone layer. It is soluble in many organic solvents.
The use of chlorofluorocarbons as an aerosol in medicine, for example: USP-approved Albuterol, has been phased out by the U.S. Food and Drug Administration. The use of a different propellant known as hydrofluoroalkane, or HFA, which does not harm the environment has been chosen as the replacement.
R-12 was primarily used in automobiles produced prior to 1994. For older vehicles, retrofits to R-134a (1,1,1,2-tetrafluoroethane) are generally recommended. Retrofits usually include a complete flushing of the air conditioning system to remove the oil. The oils used for R12 and R134a are not generally compatible, although some oils designed for conversion to R134 are advertised as compatible with residual R-12. Additionally a new compressor, expansion valve, and dryer may be needed. In some cases, all new rubber hoses are needed. It is worth noting that after changing the valves, hoses, and compressor, the only original components of the air conditioner remaining are the evaporator and condenser, neither of which have moving or delicate pieces. Replacement components are usually aftermarket products which are certified as R-134a compatible. Some car manufacturers offer OEM replacement options for older R-12 air conditioning systems.
Dichlorodifluoromethane is an inert gas that has a long history acting as a refrigerant, allowing us to stay cool in the summer, and as a spray propellant for important consumer substances. Dichlorodifluoromethane owes many of its desirable properties to its C-F bonds and synthesis involves organofluorine chemistry. Despite many uses, the gas has been isolated as a major contributor to ozone depletion and it is currently banned for production in the United States. Dichlorodifluoromethane use in the United States is currently regulated and substitutes for dichlorodifluoromethane are promising, although they too have their drawbacks.
Identification:
Synonyms14: dichlorodifluoromethane; algofrene type 2; arcton 12; arton 6; carbon dichloride difluoride; CF 12; CF 12(halocarbon) CFC 12; CFC-12; chladone 12; dichlorodifluoromethane (CCL2F2); dichlorodifluoromtheane (DOT French); dichlorodifluoromethane (DOT); diclorodifluorometano (DOT Spanish); difluorodichloromethane; dymel 12; electro-CF 12; eskimon 12; F 12; F 12 (halocarbon); F-12; FC 12; FCC 12; FWK 12; fluorocarbon 12; forane 12; freon 12; freon F-12; freon ® 12; frigen 12; frigen R12; fron 12; gas refrigerante R-12 (DOT Spanish); gaz refrigerant R-12 (DOT French); genetron 12; genetron ® 12; halon 122; halon ® 122; HC 12; isceon 122; isotron 12; khladon 12; ledon 12; methane, dichlorodifluoro-; propellant 12; R 12; R 12 (refrigerant); refrigerant 12; refrigerant gas R-12; refrigerant R 12; SDD 100; and ucon 12.
Refrigerating compounds are often referred to by their standard refrigerant designation codes, proposed by The American Society of Heating and Refrigeration Engineering in 1957 [21], prefixed by CFC for chlorofluorocarbon or R for refrigerant. The code is three digits with the number of fluorine atoms in the ones place, the number of hydrogen atoms plus one in the tens place and the number of carbon atoms minus one in the hundred.s place. Thus, dichlorodifluoromethane in ASHRAE is R-012 or CFC-012, but the zero is usually dropped to give CFC-12.
History: In the world of 2005, if we need a cold drink we might go to the refrigerator for a few ice cubes or if there is a fancy model of refrigerator available, then we might have ice water right on tap! Things weren.t always like this however, that is before modern refrigeration.
In the world of 1810 in Cuba, the ice for our iced drink would need to be imported from the New England states at more than 500 dollars per the ton10 . that.s a lot of 1810 money! Obviously ice is a very important thing if Boston, at the same time, exported approximately 65,000 tons10 of ice per year; this is before mechanical refrigeration. Ice traditionally has been very important not only in good drinks, but it has also been critical to hospitals. It is then appropriate that a doctor, Scottish Dr. John Gorrie, received the first patent for mechanical refrigeration in 1842 to help his feverish patients1.
After the advent of mechanical refrigeration, the need for ice shipped from temperate climates began to drop10. By 1855 the man made ice was being used in breweries and meat plants10, but the new ice machines weren.t without problems. First, the refrigerant of choice for the 19th century ice machine is ammonia, which has the drawbacks of being highly toxic, corrosive, and difficult to compress [1,8,10]. The net result is that the ice machines were massive (as big as a typical kitchen), steam powered (the best source of energy in the 19th century for large equipment . needing constant boiler attendance), required a lot of maintenance and were the source of industrial accidents10. An alternative had to be found!
Chemists, on the job, made a technological breakthrough: Sulfur dioxide is compressed readily and has a good latent heat* of 25 kJ/mol [8]! Chemists and physicists were able to put a kitchen sized version of the refrigerator on the market after World War One [10]. Unfortunately, sulfur dioxide isn.t the most pleasant refrigerant: Early refrigerators leaked and if they didn.t, sulfur dioxide is corrosive, so they soon would [8]. Additionally, sulfur dioxide is noted for its odor [10].
These early refrigerants were just not satisfying the public: they wanted something that would not stink up the house, burn it down, or kill them outright! It is with this criterion in mind that Frigidaire Division of GM set out to come up with a solution. They appointed Robert McNary, Thomas Midgley and Albert Henne [10] to the task of finding performing, inert refrigerants for use in the household. It is this team that discovered dichlorodifluoromethane as a refrigerant in 1928 [21].
*Latent heat is described as .a change of state without a change in temperature. [2] or basically the amount of energy that a refrigerant can absorb per refrigeration cycle through changing back and forth between the liquid and gas state.
Why are some Refrigerants better than others?
Toxicity: Up until the discovery of Freon, Dupont.s trade name for dichlorodifluoromethane, the only available .classical. refrigerants NH3, SO2 and CH3Cl all had great drawbacks and Freon was a welcomed alternative [10]. One of the primary goals in new refrigerant research at the time was that the new refrigerant be non-toxic. Chlorofluorocarbons decrease in toxicity and, very desirably, decrease in boiling point with increased C-F bonding [5]. With two C-F bonds Freon is non-toxic and boils around -29.8°C [2]. The toxicity of Freon is perhaps best demonstrated when Thomas Midgley Jr., the discoverer of CFC-12, famously filled his lungs with Freon and extinguished a candle at a meeting of the American Chemical Society in1930 [8]. The only real danger occurs if Freon is exposed to flame, according to Dupont.s Freon MSDS, the gas may decompose into its parts (HF and HCl) and, according to Scott Specialty Gases. Freon MSDS [18], the gas may decompose into the chemical warfare agent phosgene CCl2O [2,18].
Desirable Properties: When the Midgley team was looking for refrigerants efficiency was high on their list of desirable properties; it takes less power to run a refrigeration compressor if the refrigerant is easily compressible. Thus, vapor pressure and boiling point became paramount. For a temperature of about 40°C inside the refrigerator, the refrigerant needs to boil below -10°C [8] and above -60°C [5]. The refrigerant should also be inert, for safety, and low cost so that customers can afford systems. With this in mind, here is an example from Dr. William Gumprecht.s Refrigerants for the 21st Century online class at Kennesaw State University [8]:
CO2 seems like it would be a great refrigerant: it.s low cost, non-toxic, non-flammable and doesn.t react with much. The big problem, however, is that at -25°C CO2 has a vapor pressure of 15 atm; this is the temperature at which we want to expand the gas to absorb heat. An even bigger problem is that at 50°C CO2 has a vapor pressure of greater than 60 atm; this could simply blow the refrigerator apart!
Chlorofluorocarbon Uses:
CFC production, including Freon production, peaked in the mid-1980s [8,15]. The main applications of CFC.s have been use as refrigerant gases, propellants and blowing agents among others [15,21].
Refrigeration: We.ve all experienced air conditioning before; an ice cold room on an 85° day! Air conditioning is just refrigeration for a large space. As a refrigerant, R-12 is desirable because of its many exceptional properties, which we.ve already discussed, but how does refrigeration keep us so cool on that hot day?
Refrigeration is nothing more than the transfer of heat, Qc, from a cooler area to a warmer area. This idea is counter-intuitive because we generally think of heat transfer from hot to cold, but the idea works because mechanical pumping energy is required to proceed.
The basic principle behind mechanical refrigeration is the pumping of a low boiling .refrigerant. around a closed circuit system. On its journey through the refrigeration loop the liquid refrigerant is evaporated in coils, inside the cold cabinet, and heat energy, Qc, from the refrigerator is absorbed. It is through this process that the cabinet is cooled. The vapor is then compressed, giving an elevated boiling point, and allowed to condense in a set of coils outside the cabinet. It is in these coils that the refrigerant then gives up the absorbed heat Qc to the environment. The process is called the Clausius-Rankine cycle [20].
The coefficient of performance for the Clausius-Rankine cycle is given by abs(Qc/W) or the amount of energy removed, divided by the amount of work it took to remove that energy [20]. Thus, the amount of heat which can be removed per refrigeration cycle is important, which pertains to the latent heat of a given refrigerant (68 BTU / pound for Freon) [2].
We see refrigeration systems utilizing R-12 all the time: If a car is built before 1994, and is equipped with air conditioning, chances are that it.s charged with R-12. However, R-12 use is prohibited in new vehicles after 1994 in accordance with the Montreal protocol.
Blowing and Propelling: R-12 or CFC-12 makes a desirable blowing and propelling agent because it is non-reactive, non-toxic and a gas at room temperature. As a blowing agent, before the 1990 clean air act, CFC 12 was used on the space shuttle to blow in foam insulation in important parts of the shuttle where foam structure is critical [4]. As an aerosol propellant CFC 12 can be used in several important consumer applications21. To treat jungle fever, CFC 12 was produced as a canned aerosol, and the customer could simply spray themselves down with boiling Freon to keep cool! Of course, too much Freon in one spot may cause frostbite [2].
Environmental Problems:
Dichlorodifluoromethane, that we.ve all come to depend on, unfortunately is associated with some gigantic environmental problems. One of the main selling points of Freon in the 1930.s was that it didn.t kill people because it was inert. The reason Freon is inert is because its C-F bonds are hard to break and thus very stable. Freon is so stable in fact, that it cannot be removed from the atmosphere by earth.s normal processing system involving rain and hydroxyl radicals [3,13,17]. CFC-12 has a life of 102 years [6,21] and that lifespan gives the gas plenty of time to make it into the upper stratosphere where it is decomposed by solar radiation. After CFC-12 decomposes, free chlorine radical can destroy ozone. Ozone is responsible for stopping harmful ultraviolet radiation from the sun, the kind that causes skin cancer, yet it is only present in small amounts, 3 parts in 107 parts atmosphere are ozone [17], in the stratosphere.
Ozone is naturally produced and destroyed in the atmosphere at high altitude ~30 km by reaction of oxygen and solar radiation though the Chapman reactions21:
Natural Ozone Production [17, 21]:
(3) O2 + h. . O + O ; . < 242 nm (UV-C) in the upper atmosphere.
(4) O2 + O + M . O3 + M ; M is a neutral atom like oxygen or nitrogen.
Natural Ozone Destruction 17, 21:
(5) O3 + h. . O + O2 ; . = 240-320 nm (UV-B)
(6) O3 + O . 2O2
In 1971 Crutzen [3] provided additional natural reactions involving nitrogen [3,17,21]:
(7) NO + O3 . NO2 + O2
(8) NO2 + O . NO + O2
Now, the artificial reactions that occur as a result of CFC release: When a solar photon strikes a chlorofluorocarbon, such as CFC-12, chlorine can be released to catalytically destroy ozone [12,13,21].
Chlorine acts as a catalyst to destroy ozone by the following process [3,12,13,17]:
(9) CCl2F2 + h. (. < 220 nm) . Cl + CClF2 [17, 21]
(10) O3 + h. . O + O2
(11) O3 + Cl . ClO + O2
(12) O + ClO . Cl + O2
(13) Net: O + O3 . 2O2
These reactions were put forth by Molina and Rowland in 1974 [12]. Note that this process requires free oxygen atoms to proceed. It was originally believed by Molina and Rowland that ozone depletion by chlorine radical could only occur in the upper atmosphere where there is plenty of free oxygen present13.
Also put forth are terminating reactions which form temporary reservoirs. The most important terminating reactions are those involving HCl, ClNO3 and HOCl [3,13]:
(14) Cl + CH4 . HCl + CH3 [9]
(15) ClO + NO2 + M . ClONO2 + M
(16) ClO + HO2 . HOCl + O2
However, these reservoirs are only temporary and the radicals can be regenerated by the following reactions [13]:
(17) HCl + OH . Cl + H2O
(18) ClONO2 + h. . Cl + NO3
(19) HOCl + h. . Cl + OH
Because of these reactions, chlorine radical only exists in the form necessary to destroy ozone for a small portion of time, but it still seems to get the job done.
Polar Ozone Loss:
When we hear someone talking about ozone loss, most people probably think about the Antarctic ozone hole discovered by Fahmar et al. in 1985. The freely distributed picture at right is from Cambridge and depicts the ozone hole over Antarctic in 1991. 1 Dobson (DU) = 10-3 atm*mm . 2.69 x 1016 molecules*cm-3 at STP [21].
Molina and Rowland predicted [13] that catalytic ozone destruction near the poles would decrease due to a decrease in solar radiation at the poles. The sun.s rays strike the poles indirectly, so not much radiation is available to break down the reservoir species formed in 14-16. Additionally, they thought that the decreased temperature would slow reactions 17 and 18.
Fahmar suggested a possible link to stratospheric chlorine concentrations and the decomposition of CFC.s. Somehow ozone over Antarctica was being devastated!
There was a buzz in the scientific community and several different theories about ozone depletion were put forth. It was known that polar stratospheric clouds (PSC), made mainly from HNO3.3H2O [13, 21,22] or ice [22], float over Antarctica. With nitrogen devoted to polar clouds, it is unavailable for use in radical terminating reaction 18. Chlorine is activated on PSCs by the following primary reactions [7,13,17,22]:
(20) ClONO2 + HCl . Cl2 + HNO3
(21) ClONO2 + H2O . HOCl + HNO3
(22) HOCl + HCl . Cl2 + H2O
These reactions allow chlorine to be more easily photolyzed as Cl2 [13]. Additionally, nitrogen that could form ClONO2 species, which break the catalytic cycle of the chlorine radical, is used up by these reactions 20-22 [13].
Molina and Molina [11] put forth a set of reactions suggesting that chlorine from CFC.s was the main culprit in ozone depletion over Antarctica. Only this time, the reactions involve neutral molecules in the PSC.s denoted M in reactions [3,11,13, 21]:
(23) 2ClO + M . Cl2O2 + M
(24) Cl2O2 + h. . 2Cl + O2
(25) 2(Cl + O3 . ClO + O2)
(26) Net: 2O3 + h. . 3O2
This reaction involves the new species chlorine peroxide. The reactions were first verified to be the mechanism of ozone depletion over the poles by Solomon et al. in 1986. Further evidence came with a series of experiments from 1986-1987 and CFC release eventually was proven responsible for two thirds of the polar ozone depletion13. It is amazing that CFC.s released from industrial nations in the northern hemisphere can destroy 99% of the ozone over remote Antarctica thousands of miles away! Luckily, steps are being taken to control the release of CFC.s.
CFC Regulation
Greenhouse Gas verses Ozone Depleting Gas: It should first be noted that a greenhouse gas is not the same thing as an ozone depleting gas. An ozone depleting gas, like CFC-12, destroys ozone. A greenhouse gas, like CO2, holds warm air close to the earth.s surface. There is strong, verified evidence that ozone destruction takes place (see above), but it is difficult to tell whether global warming is actually taking place.
The reason that it.s so difficult to verify global warming is because we know it.s already happening16! Take the moon for example: it is a known fact that the moon has no greenhouse effect and because there is no gas to retain heat it is very cold on the moon. The global warming effect on earth, due to .greenhouse. gases in the atmosphere, can be linked to about a 33°C rise in temperature16. So, normal global warming is good because we.d all die without it! The question is whether the gases we are putting into the atmosphere are enhancing this warming effect to the point where our climate and lifestyle will be affected.
Laws: Substances in the atmosphere are assigned two numbers: a global warming potential (GWP) with CO2 set arbitrarily to one and an ozone depletion potential (ODP) with CFC-11 set arbitrarily to one [21]. These can be expressed mathematically as follows [21]:
ODP = .O3(x)/.O3(CFC-11)
Dichlorodifluoromethane control began in 1979 with an EPA ban on Freons used for cosmetic propellants [21]. The discovery of the ozone hole in 1985 has further driven regulation [21].
The first major international law signed into effect to deal with the release of CFC.s and ozone depletion was the Montreal Protocol, signed in fall of 1987 [19] in Montreal Canada [21]. The treaty and its amendments phase out the use and production of ozone-depleting chemicals with a ten year grace period for developing countries. Industrial nations stopped using CFC.s in large amounts in 1996 and .developing. nations such as Mexico are supposed to stop use by 2010 [19, 21].
The second major international law is the Kyoto Protocol signed in 1997, which seeks to restrict emission of greenhouse gases over a period of time and restrict ODP.s missed by the Montreal Treaty. However, treaties can hurt a country.s bottom line; especially when there isn.t enough convincing evidence to back up the greenhouse effect theory. Thus, the United States has refused to sign up for Kyoto until the evidence is more concrete; we are a knee jerk reaction society after all.
Dichlorodifluoromethane Alternatives: Although production is stopped, pre-ban CFC-12 can still be purchased new in the box at approximately $500 for thirty lbs, but chemists are on the lookout for good CFC-12 alternatives.
CO2 is recommended to replace CFC.s for blowing applications21, but all of the refrigeration factors discussed above must be accounted for when looking for new refrigerants.
Currently, chlorofluorocarbons are being phased out and replaced with fluorocarbons. The idea is that if there isn.t chlorine in the molecule, then it won.t be able to destroy any ozone (giving an ODP of zero). However, the drawback is that C-F bond absorbs far more infrared radiation than even CO2 [8], thus these new fluorocarbons generally have a high GWP. Take FC-116 (C2F6) for example, it is emitted to the atmosphere by the Hall aluminum process and sports an atmospheric life of 10,000 years with a GWP of 95008.
The ideal alternative refrigerant has all of the properties previously listed, is non-toxic, has a low vapor pressure at the right temperatures, doesn.t destroy any ozone, and doesn.t absorb very much infrared radiation. This is a hard bill to fit, but chemists are up to the challenge.
According to SUVA, Dupont.s refrigeration division, the suitable legal alternative to CFC-12 is R-134a1, 8, 21. Both ODP and GWP must be kept in mind when looking for alternative refrigerants, and ideally both ODP and GWP would be zero. R-134a has a formula CF3CH2F and a GWP100 Years of 1300 [6,21] and an ODP of zero (it doesn.t have any chlorine to release). CFC-12 has a GWP100 Years of about 8500 [8, 21], so R-134a is probably a good trade in terms of environmental impact.
Hydrocarbons, such as propane, butane, iso-butane, cyclohexane, and cyclopentane have also been used as environmentally safe refrigerant gases after refrigeration process redesign21.